CONSOLE OPERATING MODES

  • You must enter your secret code before disarming the system (Off or Chime Mode).

  • To select Home, Away, or Test Mode, enter your user code and press the desired mode button.  

  • You can “Quick Arm” to Chime, Home, or Away Mode by holding the desired mode key down for two seconds.  

 24-HOUR PROTECTION BUTTONS   

  • The FIRE and EMERGENCY buttons on the Console and the wireless keypad are always active.  
  • Press and hold the appropriate button for three seconds to sound an instant alarm. Disarm the Console to OFF or Chime to silence the alarm.  

 EVACUATION PLANNING  Top of Page

For systems that include fire protection, UL requires that the following information be available to the users of the system.

 The following procedures are to be discussed with the family:

  •  Draw up a floor plan showing two exits for each room.
  •  Status of bedroom doors.
  •  Familiarity with alarm signals.   
  •  Crawling and holding breath.
  •  Escape fast. No stopping for packing.    
  •  Meet at designated outdoor spot.
  •  Emphasize that no one is to return to a burning house.
  •  Fire department notification from a neighbor’s phone.
  •  Periodic rehearsal is to be conducted.   
  •  Testing of door during a fire and use of alternate escape route if door is hot to touch.

OFF MODE   Top of Page

  •  Use this mode to disarm the burglary portion of the system.        
  •  Switching to Off Mode stops any alarms in progress.                  
  •  The 24-hour buttons are still active in Off Mode and can be triggered by pressing the [FIRE] or [EMERGENCY] button.               
  •  Switch to Off Mode by entering a user code, then press [OFF].
  •  When the system is disarmed to Off Mode, the Console will sound one “Gong”.
  •  If an alarm has occurred, multiple beeps will sound after disarming and the sensor light for the
  • sensor(s) that caused the alarm will flash.           
  • Note: In Off Mode, protected doors and windows cannot trigger the burglary alarm.

CHIME MODE   Top of Page

  • Chime Mode is for monitoring entries and exits without causing alarms.
  •  Use Chime Mode as an “automatic door chime” when at home.    
  •  Opening any protected door or window causes the Console to sound a “ding-dong”.           
  •  Select the Chime Mode by entering a user code, then press [CHIME].      
  •  You can enter Chime Mode from Off Mode by holding down [CHIME] for two seconds.
  •  When the system is switched to the Chime Mode, the Console will sound a “Gong” and one “Beep”.           
  •  Going to Chime Mode disarms the system and stops any alarms in progress.

HOME MODE   Top of Page

  • Use this mode when sleeping or when anyone is staying inside.
  • Home Mode causes an instant alarm when any perimeter sensor is triggered.        
  • Home Mode causes a delayed alarm when any exit/entry sens or is triggered (except in Home Ins tant Mode when they are instant).             
  • Alarm siren stops automatically after five minutes and the system will remain armed. 
  • Home Mode ignores all interior sensors (motion detectors, etc.).
  • Arm to Home Mode by entering a user code, then press [HOME].                                              
  • You can “Quick Arm’ to Home Mode from Off or Chime Mode by holding down [HOME] for two seconds.
  • When the system is armed to the Home Mode, the Console will sound a “Gong” and two “Beeps”.
  • Enter a user code and press [OFF] or [CHIME] to disarm from Home Mode and/or stop the alarm siren • If an alarm has occurred, multiple beeps will sound after disarming and the sensor light for the sensor(s) that caused the alarm will flash (switch to Off Mode again to stop flashing alarm memory light).

 CAUTION: MULTIPLE BEEPS WHEN DISARMING SIGNAL THAT AN ALARM HAS OCCURRED. USE CAUTION, AN INTRUDER MAY STILL BE PRESENT.

SECURE EXIT   Top of Page

  • If the system is already in the Home Mode and you want to exit the premises while leaving someone inside with the system still armed in the Home Mode, enter a user code and press [HOME]

  • A “gong” and two “beeps” will sound and the HOME light will blink for 30 seconds. No exit delay beeps will sound during the silent Exit Delay.  
  • You can leave through a door with a delayed perimeter sensor during the 30 second Exit Delay without causing the Console to begin an Entry Delay.

HOME INSTANT MODE   Top of Page

  • If the system is already in the Home Mode and you want to make all exit/entry sensors instant, press [HOME] for 2 seconds.

  • A “gong” and two “beeps” will sound and the HOME light will blink continuously.
  • Because all exit/entry sensors will now cause an instant alarm when in Home Mode, the    Console must be disarmed before opening any exit/entry delay door.

MANUAL BYPASSING OF SENSORS   Top of Page

  • Manual bypassing of sensors in the Home Mode allows you to arm the system at night with open windows, while still having perimeter protection with other closed doors and windows.

  • The Console will resist arming with open door or window sensors.          
  • Four high-low beeps will sound to warn you that something is open and the system will remain in the previous mode.  
  • Lit sensor status indicators will show which sensors are open.   
  • To manually bypass the open sensors, arm the system again within 5 seconds.        
  • A “gong” and two “beeps” will sound, the HOME indicator will light, and the open sensors will be bypassed.

 WARNING: Bypassed sensors cannot cause an alarm. 

AWAY MODE   Top of Page

  • Use this mode when no one will be staying home
  • Away Mode causes an instant alarm when any perimeter sensor is triggered.
  • Away Mode causes a delayed alarm when any exit/entry sensor is triggered.
  • Away Mode causes an instant alarm when any interior sensors (motion detectors, etc.) are triggered. The interior sensors will be delayed if an exit/entry sensor is triggered first.
  • Alarm siren stops automatically after five minutes and the system will remain armed. This can occur an unlimited number of times.
  • Arm to Away Mode by entering a user code, then press [AWAY]. 
  • You can "Quick Arm" to Away Mode from Home, Chime or Off Mode by holding down [AWAY] for two seconds.

EXIT DELAY  (for leaving the premises) Top of Page

  • When the system is armed to the Away Mode, a Gong and three Beeps will sound.
  • During the 60 second Exit Delay, "beeps" sound ( double beeps during the last 10 seconds) and the Away light blinks.
  • The exit delay gives you 60 seconds to leave the premises through an exit/entry door without triggering an alarm.
  • Re-entering during the Exit Delay will extend the Exit Delay another 60 seconds one time only).
  • When the Exit Delay is over, one "gong" sounds to warn you that the system is fully armed.

ENTRY DELAY (for entering the premises) Top of Page

  • The Entry Delay gives you 30 seconds to enter the premises through an exit/entry door without triggering an alarm.
  • If an exit/entry sensor is triggered, starting the Entry Delay, the interior sensors will also become delayed (this allows motion in the premises during the Entry Delay).
  • During the 30 second Entry Delay, "beeps" will sound.
  • When the Entry Delay is over, the Console will go into full alarm and sound the siren if it not disarmed to the off or chime mode.
  • If an alarm has occurred while you were gone, multiple "beeps" will sound after disarming the system and the sensor light for the sensors that caused the alarm will flash (switch to Off Mode again to stop the flashing alarm memory light). 
  • CAUTION: MULTIPLE BEEPS WHEN DISARMING SIGNAL THAT AN ALARM HAS OCCURRED.  USE CAUTION, AN INTRUDER MAY STILL BE PRESENT!

MANUAL BYPASSING OF SENSORS    Top of Page

  • Manual Bypassing of sensors in the Away Mode allows you to arm the system with open doors and windows, while having perimeter protection with other closed doors and windows.
  • The Console will resist arming with open door or window sensors.
  • Four high-low beeps will sound to warn you that something is open and the system will remain in the previous mode.
  • Lit sensor status indicators will show which sensors are open
  • To manually bypass the open sensors, arm the systems again 5 seconds. 
  • A "gong" and three "beeps" will sound, the AWAY indicator will light, and the open sensors will be bypassed.

Warning: Bypassed sensors cannot cause and alarm.

TEST MODE  Top of Page

  • Even though this is a self-monitoring supervised system, the National Burglar and Fire Alarm Association recommends that all security systems should be tested manually on a regular basis.
  • The Console must be in Off Mode before going to Test Mode.
  • Switch the Console into Test Mode by entering a user code and pressing TEST].
  • When the system is switched to the Test Mode, a "Gong" and four "Beeps" will sound.
  • Holding down the [TEST] button will light all of the Console’s indicators.
  • The sensor status lights will flash for each sensor programmed into the Console.
  • Go to each sensor and press its test button or open and close the protected opening.
  • To test the wireless keypad, press the wireless keypad’s key.
  • A "bing" will sound as each sensor is tested.
  • As each sensor is tested, the sensor status light for the sensor will stop flashing and return to showing the current status of the sensor.
  • Continue testing until there are no flashing status lights.

NOTE: If the Console is left unattended in Test Mode, it will automatically switch back to Off Mode after 3 minutes.

 

SYSTEM TROUBLE INDICATIONS  Top of Page

  • The DVS-1200 Console is a self-monitoring supervised wireless system.
  • If the Console detects a problem with any of the supervised system sensors or backup battery, it will display the appropriate trouble indication and, if monitored, report the trouble to the Central Station through the communicator (depending on communicator programming).

        Central Station Monitoring Service

  • CONSOLE LOW BATTERY  Top of Page
  • The Console constantly charges and monitors the optional backup battery (if installed).
  • If the backup battery condition is abnormal, the POWER light will indicate the trouble.
  • The POWER indicator normally glows when AC power is on.
  • With a charged backup battery installed, if the Console looses AC power, the POWER indicator will dim as the Console runs on the backup battery.
  • If the backup battery is low, recharging, or not installed, the POWER indicator blinks when AC power is present.
  • If the AC power is off and no backup battery is installed, the POWER indicator will be off (in this case the system has no power and is disabled).
  • Normal battery life for the type of backup battery used in the Console is 5-7 years. If the battery does not take a charge in 72 hours, it should be replaced.

SENSOR LOW BATTERIES  Top of Page

  • When the BATTERIES indicator on the Console blinks, one or more sensors have a low battery.
  • Press [*] for one second to view sensor status. Sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. Any trouble indications will follow during the five second status cycle.
  • Replace the sensor’s battery as described in their instructions.
  • Switch to Test Mode after replacing the sensor battery and completely test the system (see Test Mode). Switching to Test Mode clears the low battery indication.

SENSOR RADIO TROUBLE  Top of Page

  • When the TROUBLE indicator blinks, one or more sensors have not reported status during the eight hour status time window.
  • Press [*] for one second to view sensor status. The sensor status indicator for any sensor that has not reported in will light along with the TROUBLE indicator. Any low battery indications will follow during the five second status cycle.
  • Switch to Test Mode after servicing the sensor and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.

VIDEO DEMO

Home Page

Official PayPal Seal

MAIN INDEX

[ Home Page ] [DVS-2400 ] [ DVS-1200 ] [ PERS-2400A Medical ]
[ Linear Dual-824 ] [ Linear Video Demo ] [ABOUT THE MFG.
[Monitoring Service [ Central Station ] [ Monitoring Agreement ] [ Monitoring Payment Plans ] [ Mfg. Price Lists] [ Shopping Cart Order

INDEX #2

[Linear Accessories] [X-10 Add-ons] [ Apartment Security] [ Cellular] [Extended Range] [Faq's] [Installation] [Equipment Placement] [Door Sensors] [Fire Detectors] [ Window Sensors] [Warranties] [Renters/Condos] [Seniors on Medicare] [Security Tips

BUSINESS  OPPORTUNITIES  PROGRAMS  AVAILABLE  NOW

[CONTRACTORS] [DEALERS] [ DISTRIBUTORS] [WHOLESALERS] [APPLICATION FORM]

[SELF-DEFENSE PRODUCTS ]

Copyright © 2000 WIDE-WORLD-ONE- All rights reserved